Energy Recovery Ventilator For Passive House
Energy Recovery Ventilator For Passive House

Energy recovery ventilator integrates multiple functions, including heating, cooling, purification, dehumidification, humidification, sterilization, total heat recovery.

+86-13501150965
admin@paulaircn.com
Product Details Product Parameters Product Application

Energy Recovery Ventilator For Passive House

Product Introduction

The Paulair Five-Constant All-Air system integrates multiple functions, including heating, cooling, purification, dehumidification, humidification, sterilization, total heat recovery, and bypass operation for transitional seasons. 

Outdoor air undergoes a three-stage filtration process for dust removal and precise temperature and humidity treatment, effectively blocking pollen, smog, and other particulate pollutants. This provides a protective barrier against allergens, especially for individuals with sensitivities.

With a heat recovery efficiency of over 75%, the system operates with high energy efficiency. 

It can also be equipped with the exclusive NANOE technology to prevent indoor air from becoming dry, ensuring a consistently comfortable indoor environment throughout all seasons.


图片30

五恒一体机_副本

Product Type

图片31

Five Constant Features

Constant Temperature & Pure Cleanliness
Quiet and Comfortable, creating an indoor space as serene as a forest.

Fresh Air Filtration Efficiency up to 99%
Effectively removes over 99% of PM2.5 and TVOC. Ultraviolet sterilization reaches up to 99%, while activated carbon and negative ions eliminate odors—returning a clean, pollution-free environment to your home.

Purified Air & Whole-Room Ventilation
The entire house’s air is replaced 1.5 times per hour, achieving true air circulation. No need to open windows to breathe clean air—stay indoors and enjoy every breath of fresh, purified air.

Constant Temperature
Even temperature distribution delivers spring-like comfort all year round.

Comfort temperature maintained at 20–26°C
The temperature stays consistently around 24±℃ in summer and 20±℃ in winter, avoiding the discomfort caused by sudden hot or cold fluctuations.

Radiant tubes provide continuous and even temperature adjustment
Radiant heating and cooling ensure uniform temperature with minimal variation, offering comfortable warmth at the feet and coolness overhead

Constant Humidity
Bid farewell to dryness and dampness, and enjoy comfort that feels as natural as the outdoors.

Humidity range: 35%–65%
Indoor humidity is consistently maintained between 35% and 65%, the range most comfortable for the human body.

A dry and pleasant environment
The space remains free from mold, mustiness, and excessive dryness, effectively reducing health issues caused by both humidity and arid conditions.

Constant Oxygen 0₂
Close to nature, regularly refreshing indoor air

CO₂ < 400 PPM
Efficiently purifies secondhand smoke and filters formaldehyde

24/7 efficient purification and filtration
Whole-house air is replaced 1.5 times per hour, achieving true air circulation without the need to open windows. Breathe clean, fresh air indoors—every breath pure and revitalizing.

Constant Quietness
Serene and soothing, creating an indoor space as tranquil as a forest.

Zero indoor units, zero noise.
No equipment is installed inside the room, eliminating any bothersome noise and ensuring a full night's restful sleep.

Uniform indoor temperature with no draft sensation
Using low-temperature-difference radiant heat exchange, the indoor temperature is balanced within the range ideal for human comfort. 

The temperature is even, without direct cold drafts or strong stimulation—no noise, just natural and pleasant comfort.


Five-Constant System · Fresh Air Exchange

Temperature Control
Ensures supply air temperature is 2–3℃ lower than indoor temperature, balancing indoor temperature differences, reducing load on the main unit, and lowering operating electricity costs.

Full Fresh Air Exchange
Up to one complete house air change per hour. Supply and exhaust air follow completely independent paths to avoid cross-contamination.

High-Efficiency Dehumidification
Fresh air temperature and humidity are treated separately, making dehumidification and humidification more comfortable. Maximum dehumidification capacity in summer can reach 40%.

Steam Humidification
Humidification is efficient and stable, with maximum humidification capacity in winter up to 60%. High-temperature sterilization ensures no contamination.

Indoor Slight Positive Pressure
Exhaust air volume is about 80% of fresh air volume, creating a slight positive pressure indoors. Fresh air pushes out stale heated air, achieving displacement ventilation while preventing outdoor polluted air from flowing back inside.

High-Efficiency Filtration
Effectively filters PM2.5, aerosols, and other particles with filter efficiency exceeding 99%, keeping indoor air clean and reducing household cleaning burden.


Complete Fresh Air Displacement
Independent air inlets introduce fresh air, which is then effectively directed to push stale indoor air out through kitchens and bathrooms. The supply and exhaust paths are entirely separate—without cross-contamination or air mixing—for a healthier environment.


Five-Constant System · Fresh Air Displacement
High-Efficiency Dehumidification

Fresh air temperature and humidity are treated separately, enabling more comfortable dehumidification and humidification. Maximum dehumidification capacity in summer can reach 40%.

Steam Humidification
The humidification method is efficient and stable, with a maximum humidification capacity in winter of up to 60%. It employs high-temperature sterilization without causing pollution


图片32

Advantages of the Five-Constant System

图片33


Five-Constant System VS Traditional Air Conditioning

Temperature

Five-Constant System: Summer: 24–28°C, Winter: 18–22°C, temperature difference < 3°C; uniform temperature, comfortable body feel, less prone to illness.

Traditional Air Conditioning: Uneven cooling/heating, large temperature fluctuations; uncomfortable, prone to "air conditioning sickness."

Airflow Sensation

Five-Constant System: Cooling/heating via radiation; no draft sensation, high comfort.

Traditional Air Conditioning: Cold air feels harsh, hot air is dry; draft discomfort, likely to cause "air conditioning sickness."

Humidity

Five-Constant System: Relative humidity 30%–70%, temperature and humidity can be controlled independently; comfortable feel, protects furniture.

Traditional Air Conditioning: No humidity standard, only cools/dehumidifies, no humidification; prone to mold, bacteria growth, and related conditions like rheumatism/arthritis.

Oxygen Level

Five-Constant System: Full-house air replacement once per hour; ensures healthy breathing for the family.

Traditional Air Conditioning: No such function, poor air circulation; may lead to respiratory illnesses.

Air Cleanliness

Five-Constant System: PM2.5 < 50, filters formaldehyde, benzene, TVOC; provides clean air, promotes health.

Traditional Air Conditioning: No air filtration; increases exposure to air pollution and related health risks.

Noise

Five-Constant System: Operates silently; creates a quiet environment, ensures good sleep.

Traditional Air Conditioning: Fan noise around 45 dB; disturbs rest, affects health.

Energy Efficiency

Five-Constant System: Saves 30%–50% energy; reduces annual heating gas costs.

Traditional Air Conditioning: Standard energy consumption.

Smart Features

Five-Constant System: Intelligent system, remote control, real-time monitoring, easy to use.

Traditional Air Conditioning: Lacks smart functionality.

Installation (Terminal)

Five-Constant System: Ceiling height about 10 cm; saves space.

Traditional Air Conditioning: Ceiling height about 30 cm; occupies more space.


Advantages 

Five-Constant System Dehumidification and Dryness Relief – Warm, Moist, and Comfortable
Medical-grade filter with triple-stage filtration and strong sterilization + UV disinfection, removing over 99% of PM2.5 and dust particles from the air, continuously delivering fresh air indoors.

Fresh Air Displacement – Clean Oxygen, Fresh and Invigorating
24-hour complete air replacement – no stale air indoors, quickly expelling indoor pollutants.




SPECIFICATION

PAULAIR Five-in-One All-Air Environmental Control Unit Technical Specifications
SpecificationBEY3.0-E100-F300HDBEY3.0-E140-F600HDBEY3.0-E160-F800HDBEY3.0-E180-F1000HDBEY3.0-E200-F1000HD
Outdoor Unit ModelBEY-100-K2BEY-140WQ-K2BEY-160WQ-K2BEY-180WQ-K2BEY-200WQ-K2
Specification3HP Ceiling Type5HP Cabinet Type6HP Cabinet Type7HP Cabinet TypeSmall 8HP Cabinet Type
Fresh Air Volume (m3/h)30060080010001000
Circulated Air Volume (m3/h)8001200160020002200
Supply Air Static Pressure (Pa)135110131110131
Sensible Heat Recovery Efficiency (%)75%75.00%75.00%75.00%75%
Total Heat Recovery Efficiency (%)70%70.00%70%70.00%70%
Dehumidification Capacity (kg/h)8~1012~1513~1616~1918~20
Nominal Cooling Capacity (kW)7.5121415.517
Nominal Cooling Input Power (kW)2.583.914.795.346.32
Nominal Cooling EER (W/W)2.93.072.922.92.69
Rated Heating Capacity (kW)1014161820
Rated Heating Input Power (kW)2.93.854.465.085.95
Rated Heating COP (W/W)3.453.643.463.543.36
Nominal Heating Capacity (kW)61012.213.515.5
Nominal Heating Input Power (kW)2.33.914.845.256.15
Nominal Heating COP (W/W)2.612.562.522.572.52
Low-Temperature Heating Capacity (kW)5.59.910.812.513
Low-Temperature Heating Input Power (kW)2.54.44.955.535.8
Low-Temperature Heating COP (W/W)2.22.252.182.262.24
Max Input Power/Current (kW/A)3.9/18.06.0/28.06.9/32.07.4/34.07.9/36.0
IPLV(C)/IPLV(H) (W/W)4.10/3.004.28/3.184.28/3.184.28/3.194.20/3.19
Rated Water Flow (m3/h)1.32.062.412.672.92
Inlet/Outlet Pipe SizeRc3/4"Rc1"Rc1"Rc1"Rc1"
Water Side Pressure Drop (kPa)2024262832
Max Water Side Operating Pressure (MPa)
1


Discharge/Suction Side Allowable Pressure (MPa)
4.2/1.5


Max High/Low Side Pressure (MPa)
4.2/1.5


Refrigerant & ChargeR32/1.5kgR32/2.6kgR32/2.6kgR32/2.8kgR32/2.8kg
Net Weight (kg)77123123123123
Protection Class:Electrical shock protection type / Waterproof rating

Indoor Unit Dimensions (mm):

1400×300×950 / 1036×406×770

1740×500×1160 / 1736×400×1140

1740×500×1160 / 1736×400×1140

Notes:

Nominal Cooling: Outdoor dry/wet bulb temperature: 35℃/—;Outlet water temperature: 7℃;

Rated Heating: Outdoor dry/wet bulb temperature: 7℃/6℃;Outlet water temperature: 45℃;

Nominal Heating: Outdoor dry/wet bulb temperature: -12℃/-13.5℃;Outlet water temperature: 41℃;

Low-Temperature Heating: Outdoor dry bulb temperature: -20℃;Outlet water temperature: 41℃;

Unit parameters may change due to product improvements. Please refer to the actual product and nameplate for details.

Implementation Standards: GB/T 26127.2, GB/T 18430.2.


APPLICATION

Ultra-low Energy Consumption Building, Technology Residence, Basic Supporting Facilities, Villa Renovation, New Construction Roughcast.


五恒一体机应用