Wall-Mounted Air Conditioner
Wall-Mounted Air Conditioner

Wall-Mounted air conditioning is usually called fission air conditioning, it 's not limited by installation position, it's easier to match with interior decoration.

+86-13501150965
admin@paulaircn.com
Product Details Product Parameters Product Application

Wall-Mounted Air Conditioner

Product Introduction:

Location: Usually called fission air conditioning, not limited by installation position,it's easier to match with interior decoration.  

Function: Less noise, some family air-condition purification with multiple functions, can be for indoor air purification, more ventilation function of fission air conditioning, in order to protect healthy. 

Detailed installation steps for wall-mounted air conditioners. 

Remove the installation plate on the back of the indoor unit and place it at the pre-selected installation position. 

At this time, it should be kept level and leave sufficient dimensions with the ceiling and the left and right walls. 

Determine the position for drilling the holes to fix the wall panels...

空调



Maintenance Methods for Wall-Mounted Air Conditioners

1. Prevention Of Air Embolism

Ensure complete air drainage during water filling for wall-mounted air conditioners. 

Perform regular air venting for wall-mounted air conditioners. 

Check the air vent valve of wall-mounted air conditioners periodically to ensure it's in good condition.

2. Prevent Dirty Blockage

Clean the wall-mounted air conditioning system pipes regularly to remove rust, dust, and other debris. 

Add chemicals periodically to prevent copper pipes from rusting.

3. Preheating Method

This method involves installing a preheater between the fresh air supply and the surface cooler,

in addition to a chain-operated electric thermostatic air volume control valve at the wall-mounted air conditioner fresh air inlet. 

By preheating the outdoor fresh air to above zero degrees Celsius before it contacts the surface cooler, the system ensures that fresh 

air poses no threat to the cooler in case of unexpected events such as power outages, circulation pump failures, or surface cooler blockages.

4. Pay Attention To The Impact Of Outdoor Temperature

Operators should closely monitor the instrument temperature readings and promptly address any abnormalities in wall-mounted air conditioners. For areas with relatively low temperatures, the hot water valve should be appropriately opened wider.


Precautions for Wall-Mounted Air Conditioner Usage

1. Avoid placing air conditioners directly above beds to prevent direct airflow from the cold air.

2. Avoid setting the air conditioner temperature too low. 

The ideal indoor temperature in summer should be 24-27°C, with a max temp difference between indoors and outdoors of 10°C.

3. Rooms with prolonged air conditioning use require proper hygiene maintenance, as excessive dust accumulation may trigger asthma 

and other respiratory conditions.

4. When moving from outdoors to indoors, it's best to wipe off sweat with a towel before turning on the air conditioner.

5. People who frequently stay in air-conditioned environments should engage in moderate physical exercise to enhance their disease 

resistance and emergency response capabilities. It's evident that wall-mounted air conditioners require attention to several factors.

For instance, the operating temperature should not be set too low. The optimal indoor temperature in summer ranges from 24°C to 27°C, 

with the indoor-outdoor temp difference ideally not exceeding 10°C. Only by avoiding taboos can its maximum effect be better exerted.


Feature OF Air conditioner

Ultra-low Noise (25 dB)

Utilizing five major noise-reduction technologies, including silent compressor, silent motor, and silent piping system, combined with a 

high-quality compressor, double-layer silencer, and piping muffler, ensuring quiet operation with noise levels as low as 25 dB.

High-efficiency Purification (99.9% PM2.5 Removal)

Equipped with an air purification and dust removal system, featuring the patented IP high-efficiency dust collection technology, 

which effectively removes PM2.5 with a removal rate as high as 99.9%, ensuring healthy indoor air quality.

Inner-grooved All-copper Pipe

Designed with inner-grooved all-copper pipes, increasing heat exchange area for improved efficiency and energy savings.

Large-area Fine Filter

Fitted with a large-area fine filter that effectively captures fine particles in the air, ensuring clean airflow and protecting respiratory health.


SPECIFICATION

ModelEnergy ClassCooling Capacity (W)Cooling Power (W)Heating Capacity (W)Heating Power (W)Indoor Unit Size (mm)Outdoor Unit Size (mm)Indoor Unit Weight (kg)Outdoor Unit Weight (kg)Indoor Airflow (m³/h)
BEY-25GW/Y32500780--700×200×205720×330×4507.522500
BEYRD-25GW/Y325007802760750700×200×205720×330×4508.524500
BEY-26GW/Y32600810--700×200×205720×330×4508.522500
BEYRD-26GW/Y326008102860750700×200×205720×330×4507.522500
BEY-35GW/Y335001125--800×200×205805×320×5459.528560
BEYRD-36GW/Y33500112535501167800×200×205805×320×5451030560
BEY-36GW/Y336001125--850×200×205805×320×5459.528620
BEYRD-36GW/Y33600112539601030850×200×205805×320×5459.528620
BEY-62GW/Y352001670--1000×330×235865×355×55514.942.1850
BEYRD-62GW/Y352001670572016501080×330×235865×355×55514.942.1850
BEY-72GW/Y372002250--1000×330×235900×360×70515.646.61100
BEYRD-72GW/Y372002250770022001080×330×235900×360×70515.646.61100


ModelEnergy ClassCooling Capacity (W)Cooling Power (W)Heating Capacity (W)Heating Power (W)Indoor Unit Size (mm)Outdoor Unit Size (mm)Indoor Unit Weight (kg)Outdoor Unit Weight (kg)Indoor Airflow (m³/h)
BEY-26GW/Y(XY)32600812800×290×205805×315×55027
BEYRd-26GW/YXY326008122860750800×290×205805×315×5501027
BEY-35GW/V(XY)335001125850×290×205830×300×5509.529
BEYRd-35GW/Y(XY)33500112538501167850×290×205830×300×5501030.5





Application OF Wall-Mounted Air Conditioner

Automobile Manufacturing Plants, Plastic Factories, Hardware Factories, Electronics Factories, Machinery Factories, Electrical Appliance Factories, Leather Goods Factories, Garment Factories, Pharmaceutical Factories, Textile Factories, Shoe Factories And Other Types Of Factory Workshops.

Various Commercial Centers, KTV, Internet Cafes, Schools, Stations, 4S Stores, Gyms, Outdoor Sports Fields, Hotel Kitchens, Outdoor Restaurants, Car Washes, etc.


图片1